Cyclon- Technical


Cyclon Cells & Monoblocks:


Cyclon Cells and monoblocks can be custom built in any 2 volt configuration. Used extensively in industry, they perform in every demanding environment. We can provide a custom build for your particular product including design and manufacture.

 

* Operating Temperatures:Cells: -65 degC to +80 degC
Cells: -65 degC to + 80 degC
Monoblocks: -40 degC to +40 degC
 
* High shock & vibration resistance
* Cycle life - up to 3000 cycles at 30% Depth of Discharge
* Float life:
Cells -15 years at 20 degC
Monoblocks - 10 years at 20 degC
 
* Storage life more than 24 months at 25 degC, from full state of charge
 
* Recharge to 95% capacity in under 60 minutes

Applications include: hospitals, rail transport, domestic equipment,utilities, manufacturing.

Technical Specification for 2 Volt Single Cells at 25 degC
Cell Type Volts Nominal (Ah)
Capacity (10hr rate - 1.67 vpc)
Dimensions mm Weight
Kg
Diameter Height Height over tabs
D Cell (2.5Ah)
2
2.5
34
61
68
0.2
Tall D cell
(4.5Ah)
2
4.5
34
96
103
0.3
X cell (5.0Ah)
2
5.0
44
73
82
0.4
E cell (8Ah)
2
8.0
44
100
109
0.6
J cell (12.5Ah)
2
12.5
52
123
136
0.8
BC cell (25Ah)
2
25.0
65
159
174
1.7

Discharge Characteristics
Cyclon Type
Pulse Amps
Continuous Amps
D Single Cell (2V, 2.5Ah)
200
65
D Monoblock (6V, 2.5Ah)
200
50
TD Single Cell (2V, 4.5Ah)
200
65
X Single Cell (2V, 5.0Ah)
285
65
X Monobloc (6V, 5.0Ah)
285
50
E Single Cell (2V, 8.0Ah)
330
65
E Monoblock (6V, 8.0Ah)
330
50
J Single Cell (2V,12.5Ah)
400
65
BC Single Cell (2V, 25.0Ah)
665
250
Standard Cyclon Monoblocks and battery packs are available in 4,6,8 & 12 Volt tagged packs as standard. Other sizes can be made to order.

Warning: Do Not Short Circuit Cyclon Batteries.

Top of Page